A Different Kind of Data Center Project
Not every data center in Irving sits inside a purpose-built building. A meaningful share of the compute, power and cooling capacity added across the area over the past decade has arrived in the form of prefabricated or containerized modules — skid-mounted power rooms, factory-built IT pods, and modular UPS and cooling enclosures dropped onto a slab or parking pad rather than built room-by-room.
That equipment eventually reaches the end of its service life for the same reasons a conventional facility does: a lease ends, a tenant outgrows the site, capacity gets consolidated into a newer campus, or an operator standardizes on a newer modular platform. When that happens, the removal project looks different from a typical building decommissioning. You’re not demolishing a structure — you’re disconnecting, unrigging, and physically extracting a self-contained system that was designed to be delivered and installed as a unit, and now has to come out the same way.
USA Decom provides modular and containerized data center decommissioning, removal, relocation and disposition services for operators, landlords, colocation providers and enterprise IT teams across Irving and the greater Dallas-Fort Worth market.
Modular Capacity in the Irving-Las Colinas Market
Irving and the Las Colinas district sit inside one of the more established business corridors in North Texas, with direct access to State Highway 114, proximity to DFW International Airport, and a long history of corporate, telecom and technology tenants. That combination of infrastructure and connectivity has made the area attractive for both conventional data center construction and faster-to-deploy modular or containerized capacity — particularly for organizations that needed to add power, cooling or IT capacity without waiting on a multi-year build.
As data center campuses in Las Colinas and elsewhere in the Dallas-Fort Worth region continue to expand, older enterprise sites, edge deployments and interim modular installations are sometimes retired, consolidated or relocated to make way for newer infrastructure. A modular unit removed from an Irving-area site may need to travel to, or be replaced by, capacity in nearby communities such as Grand Prairie, Carrollton, Coppell, Richardson, Plano or Fort Worth as part of a broader relocation or consolidation plan.
What “Modular Data Center” Actually Covers
The terminology in this category gets used loosely, so it helps to be specific about what a removal project can involve:
- Containerized data center modules — 20-foot or 40-foot ISO-style enclosures with integrated IT space, cooling and sometimes power
- Prefabricated data center pods — larger factory-assembled IT modules, often paired with separate power and cooling modules
If you have a project coming up, use the form below to tell our team about the facility, equipment and schedule.
- Modular power rooms — skid-mounted generator, switchgear, and UPS packages that supported a modular or hybrid deployment
- Modular cooling modules — packaged CRAH, chilled-water, or DX cooling skids serving a pod or row
- Portable and relocatable data centers — units originally deployed for temporary capacity, disaster recovery or overflow that are now being retired or redeployed
Equipment commonly found in this category includes systems from manufacturers such as Vertiv (including SmartMod, SmartRow and SmartAisle platforms), Schneider Electric/APC prefabricated systems, Dell containerized deployments, and HP/HPE POD-series units including the EcoPOD 240a and EcoPOD 40c form factors. Integrated power and cooling equipment inside these modules is often built around Caterpillar, Cummins or Kohler generators; Eaton, Vertiv/Liebert or APC UPS systems; and Liebert, STULZ or Uniflair precision cooling, with electrical distribution built on Square D, Eaton, Siemens or GE components. Recognizing the manufacturer and model on the nameplate matters because it directly affects disconnection sequencing, rigging approach and, where applicable, resale potential.

How a Modular Removal Project Actually Runs
A conventional facility decommissioning is largely about clearing a room. A modular removal is closer to a controlled uninstall-and-extract operation. The general sequence typically looks like this:
1. Site and unit assessment. Confirm module type, dimensions, weight, foundation or curb attachment, and current power/IT status — live, standby, or already de-energized.
2. Utility and connectivity disconnection. Coordinate electrical isolation, fuel-line disconnection for integrated generator skids, fiber and copper cable removal, and any building-side tie-ins.
3. IT and data-bearing asset handling. Server racks, storage and networking gear are removed and staged separately from infrastructure equipment. Data-bearing devices may require appropriate chain-of-custody or sanitization procedures as part of the overall project plan.
4. Rigging and structural disconnection. Modules are typically bolted or welded to a foundation, curb or adjacent module. This connection has to be released without damaging the unit if it’s being relocated or resold intact.
5. Lift and load-out. Depending on size and site access, this may involve a crane pick, a low-boy trailer with hydraulic gantry, or a multi-axle module transporter — often the same type of equipment originally used to deliver the unit.
6. Transportation. Oversize or overweight permitting, route survey and escort requirements can apply to full-size containerized or POD-class modules depending on dimensions and weight.
7. Site restoration or turnover. Slab, curb, conduit stubs and utility connections are addressed to meet the landlord’s or next tenant’s turnover requirements.
Access and Site Conditions That Shape the Plan
Modular units are almost always installed outdoors, on a rooftop, in a yard, or on a dedicated pad — which introduces logistics questions that don’t come up inside a conventional data hall:
- Crane vs. trailer extraction. A rooftop-mounted module may require a crane pick over the building; a ground-level pad unit may load directly onto a trailer.
- Clearance and route. Overhead power lines, building overhangs, and tight yard access around an active facility all affect whether a unit can be lifted or rolled out in one piece.
- Foundation type. Concrete pad, steel curb, or elevated structural platform each require a different disconnection method.
- Adjacent operations. If the module served, or still serves, part of an active facility, sequencing has to protect uptime for systems that remain in service during the project.
- Permitting and escort requirements. Larger containerized units and PODs can qualify as oversize loads on North Texas highways depending on final dimensions, which may affect scheduling around DART rail crossings, DFW-area interchanges, and local street restrictions near the Highway 114 corridor.
Relocation vs. Retirement: Two Different Outcomes
Not every modular removal ends in disposal. Depending on age, condition and market demand, a module coming out of an Irving-area site may go one of several directions:
- Relocation to another site operated by the same company, often to a lower-cost or more strategically located facility
- Sale to a secondary market buyer looking for turnkey modular capacity without a multi-year construction timeline
- Component-level recovery, where the IT module itself is retired but the generator, UPS, switchgear or cooling skids inside it retain resale value
- Recycling and scrap processing for structural steel, copper wiring, aluminum, and electronic components that have reached end of useful life
Recoverable value depends heavily on manufacturer, model, capacity, completeness, age and condition, and it isn’t realistic to assume every module or component will carry significant resale value. That said, identifying what’s recoverable before cutting into a unit or sending it to scrap is usually worth the extra assessment time, since recovered equipment and commodity value can offset a portion of the overall removal cost.
Coordinating With Everyone Who Has a Stake in the Project
Modular removal projects in an active or recently vacated facility usually involve more coordination than a straightforward demolition:
- Landlords and property managers who need the pad, curb or roof area returned to a specific condition
- IT and network teams managing data migration, connectivity cutover and equipment chain of custody
- Facilities and electrical engineers overseeing utility isolation and de-energization
- General contractors, if the removal is part of a broader site redevelopment or tenant improvement
- Transportation providers handling permitted moves if the module is being relocated rather than scrapped
Our team works directly with these stakeholders to sequence disconnection, extraction and load-out around the realities of an occupied or recently occupied site, rather than treating the module as an isolated demolition target.
Real-World Project Examples
Projects in this category have included removing containerized IT modules and associated power skids from sites being consolidated into newer campus capacity, extracting modular UPS and cooling enclosures ahead of a property redevelopment, and coordinating crane-assisted removal of a rooftop-mounted module where the original delivery crane pad was no longer accessible. On projects of this type, our team typically separates IT-module disconnection from power-module disconnection, stages recoverable equipment separately from scrap-bound components, and sequences transportation around any permitting or route restrictions tied to the module’s size and weight. The scale of this work has ranged from a single 20-foot containerized unit to multi-module deployments in the 250 kW to 2 MW range, with larger combined retirements occasionally reaching 5 MW or more of modular capacity.
What to Gather Before Reaching Out
Because modular removal scopes vary so much by unit type, foundation and site access, it helps to have a few basics ready when you contact our team:
- Manufacturer and model, if known — Vertiv SmartMod/SmartRow, Schneider Electric/APC, Dell, HPE EcoPOD, or another platform
- Number of modules and approximate power capacity (kW or MW)
- Whether the unit is still energized, in standby, or already shut down
- Foundation type — slab, curb, rooftop platform, or elevated structure
- Site access conditions, including crane clearance and trailer route
- Whether the goal is disposal, relocation to another site, or resale
- Target timeline, including any lease, shutdown or landlord turnover deadline
- Photographs of the unit, nameplate and site access, if available
You don’t need finished answers to every item — a general description is enough for our team to start scoping the project.
Serving Irving and the Surrounding DFW Market
USA Decom provides modular and containerized data center removal, decommissioning and disposition services throughout Irving and neighboring North Texas communities, including Las Colinas, Grand Prairie, Carrollton, Grapevine, Coppell, Richardson and the broader Dallas-Fort Worth Metroplex.
If you have a modular data center, containerized IT module, or associated power and cooling system that needs to come out of an Irving-area facility, use the form below to tell us about the manufacturer and model if known, the module count and capacity, site access conditions, and your target schedule. That information lets our team put together a realistic scope and next steps for your project.