Kern County’s industrial base runs on electrical infrastructure that was often installed decades before the facility’s current tenant ever signed a lease. Oilfield service yards, agricultural processing plants, cold storage facilities, rail-served distribution centers and manufacturing buildings throughout the Bakersfield area frequently carry switchgear, panelboards, transfer switches and busway systems that have been added to, modified and re-fed multiple times since original construction. When one of these facilities is being upgraded, downsized, repurposed or vacated, someone has to safely remove that gear, and that work is rarely as simple as unbolting a cabinet from a wall.
USA Decom provides electrical equipment removal services for commercial and industrial properties in Bakersfield and throughout the surrounding Central Valley. Our work covers de-energized switchgear, panelboards, transfer switches, busway, transformers and related distribution equipment, along with the rigging, disconnection coordination, transportation and disposition planning that a project like this requires.
Why Electrical Equipment Removal Projects Get Complicated
A single low-voltage breaker swap is a maintenance task. Removing an entire switchgear lineup, a bank of panelboards, or a run of busway feeding several production lines is a construction-scale project with its own sequencing, safety and logistics requirements. The complexity generally comes from a handful of recurring conditions:
- The facility is still partially energized. Many decommissioning and equipment-removal projects happen inside buildings where other tenants, production lines or building systems remain live. Removal sequencing has to isolate the correct circuits without disrupting adjacent operations.
If you have a project coming up, use the form below to tell our team about the facility, equipment and schedule.
- The gear is old enough that documentation is incomplete. Legacy switchgear built under earlier Westinghouse, ITE, or Cutler-Hammer nameplates may still be functioning correctly decades after those brand names changed hands, but as-built drawings rarely kept pace with field modifications.
- Access is tight. Electrical rooms are commonly built to the minimum code-required footprint, with switchgear lineups, busway runs and cable trays stacked close to walls, ceilings and adjacent equipment.
- The equipment is heavy and awkward to move. Drawout switchgear sections, medium-voltage breakers and large transformer cores routinely weigh well beyond what can be handled with a pallet jack and a few laborers.
- Disposition decisions carry real financial consequences. Copper bus, aluminum enclosures and functional breakers all have recoverable value, and how that value is captured depends heavily on how carefully the equipment is removed.
Typical Equipment We Remove
Electrical equipment removal projects in this market commonly involve low- and medium-voltage gear from the major manufacturers active in California industrial construction over the last several decades. That includes Square D and Schneider Electric equipment such as PowerPact and I-Line panelboards, QED switchboards, and MasterPact NT/NW drawout circuit breakers used in Power-Zone metal-enclosed switchgear lineups. It also includes Eaton and legacy Cutler-Hammer or Westinghouse gear such as Magnum DS and DSII switchgear, Series C panelboards, Pow-R-Line distribution equipment and Pow-R-Way busway.
GE and ABB-labeled equipment, including AK and AKR frame breakers, Spectra and Spectra RMS panelboards, and ReliaGear switchboards, still appears in older manufacturing and processing facilities throughout Kern County. Siemens and legacy ITE equipment, including WL and RL frame breakers and Sentron distribution gear, shows up in similarly aged buildings. On the automatic transfer switch side, we regularly encounter ASCO Series 300, 4000 and 7000 switches, Russelectric RTS systems, and Cummins/Onan PowerCommand transfer equipment supporting standby generation at facilities with critical or backup power needs.
Busway removal is its own category of work. Whether the run is Square D I-Line, Eaton Pow-R-Way, Siemens Sentron, GE/ABB Spectra, Schneider Canalis, or a Starline trolley-style system, busway is typically overhead, energized at the source end until isolated, and installed in long continuous runs that need to be de-energized, disconnected in sections and lowered without damaging adjacent ceiling systems, sprinkler lines or cable tray.

Voltage Classes and Scope We Encounter
Bakersfield’s industrial and energy-services economy produces a wide range of electrical distribution scales. Service-yard and light-industrial buildings often run standard 208V and 480V systems fed through 400A to 1200A panelboards and switchboards. Larger processing plants, cold storage facilities and manufacturing operations frequently step up to 1600A, 2000A, 3000A or larger main switchgear sections at 480V or 600V. Facilities tied to oilfield operations, agricultural processing, or larger industrial campuses may also involve medium-voltage equipment in the 4.16kV, 5kV or 13.8kV class, including vacuum-clad medium-voltage breakers such as Eaton’s VacClad-W line. Understanding which voltage class and ampacity is involved early in the project affects everything from the isolation plan to the rigging equipment we bring to site.
Planning the Removal: What Happens Before Anything Comes Out
Before any equipment is disconnected, we work through the same core questions on every project: What is currently energized, and what needs to stay energized? Who controls the isolation points, and are they inside or outside the scope of the removal contractor? What documentation exists for the gear, and where are the gaps? What are the dimensions, weights and access path for each major component?
That planning phase typically includes a site walk to confirm equipment condition, nameplate data, ampacity and physical layout; coordination with the facility’s electrical contractor, engineer or utility on isolation and lockout/tagout sequencing; and a rigging and transportation plan based on section weights, door widths, floor loading and any elevator or dock constraints. For active facilities, this planning also has to account for adjacent operations that cannot be interrupted, which often means scheduling removal work during off-shifts, planned outages, or phased shutdown windows rather than a single continuous mobilization.
Disconnection, De-Energization and Isolation Coordination
Electrical equipment removal always starts with confirmed de-energization, not assumed de-energization. Depending on the facility, that isolation work may be performed by the customer’s electrical contractor, a utility, or another qualified party ahead of our mobilization, with USA Decom coordinating scheduling and sequencing around that work. Once equipment is confirmed de-energized, locked out and tagged, our team proceeds with disconnecting feeders, bus connections, control wiring and grounding conductors in the sequence needed to safely separate each section without leaving any conductor unexpectedly live.
Medium-voltage gear and larger low-voltage switchgear lineups often require additional coordination steps, including confirming that upstream protective devices have been opened and verified, and that any capacitor banks or stored-energy devices have been properly discharged before physical work begins.
Rigging, Disassembly and Extraction
Once isolated, most switchgear and switchboard lineups come out in sections rather than as a single unit. Drawout breaker cubicles, bus compartments and cable termination sections are typically separated, disconnected internally, and rigged individually. This section-by-section approach reduces the load on rigging equipment, makes tight doorways and corridors manageable, and allows crews to work through electrical rooms methodically rather than attempting to move an intact multi-thousand-pound lineup as one piece.
Extraction methods depend heavily on the building. Ground-floor electrical rooms with a clear path to a loading area may allow forklift and pallet-jack extraction. Upper-floor rooms, rooms behind narrow doorways, or equipment located in below-grade vaults often require chain hoists, gantry systems, or engineered rigging plans to move sections safely to a staging or loading point. Busway removal follows a related logic: sections are disconnected at plug-in units and splice joints, lowered with appropriate lifting equipment, and staged for either reuse evaluation or scrap processing depending on condition and market demand.
Working Around Active Operations
Very few electrical equipment removal projects happen in a completely empty building. More often, the electrical room being cleared sits inside a facility that still has production running, tenants occupying part of the space, or building systems that cannot go down. That reality shapes almost every part of the schedule.
We typically build removal sequencing around the facility’s actual operating constraints rather than a generic project timeline: which panels or switchgear sections feed circuits that must remain live, what shutdown windows are available, and how work zones need to be barricaded and communicated to personnel who are still working nearby. On sites with ongoing operations, clear communication with facility staff about which areas are being de-energized, when, and for how long is as important as the physical removal work itself.
Transportation and Site Logistics
Bakersfield’s position along State Route 99 and State Route 58, with connections to Interstate 5 and rail service through the BNSF and Union Pacific corridors, supports efficient equipment transportation to processing, recycling or resale destinations throughout California and the broader Southwest. For projects generating substantial equipment volume, we plan loadout around dock availability, trailer access, crane or forklift staging areas, and any street or yard restrictions specific to the property. Heavier sections, including medium-voltage switchgear and larger transformers, may require specialized trailers or additional rigging support to move safely from the building to the transport vehicle.
Asset Recovery: What Removed Electrical Gear Is Worth Evaluating
Electrical distribution equipment often retains meaningful recoverable value, and that value is easiest to capture when removal is planned with disposition in mind from the start. Functional breakers, switchgear sections and panelboards in usable condition may have resale or reuse value in the secondary equipment market, particularly for well-known manufacturer families that remain in service across many facility types. Copper bus bar, wiring and aluminum enclosures also carry commodity value even when a component’s electrical function has reached end of life.
The realistic value of any specific piece of equipment depends on manufacturer, model, ampacity, voltage class, age, completeness, and physical condition, along with current demand in the secondary market. Recovered equipment and material value won’t offset every cost on every project, but on many jobs it can meaningfully reduce net removal expense when the gear is disconnected, handled and stored in a way that preserves its condition rather than treating it as scrap from the outset.
Site Restoration and Turnover Requirements

Once equipment is out, most projects still require some level of site restoration before the space is considered turned over. That can include capping or terminating abandoned conduit and cable, patching wall or floor penetrations left by removed equipment, cleaning the electrical room, and documenting the final condition of the space for the property owner, landlord or incoming tenant. Turnover requirements vary significantly depending on whether the space is being re-leased, redeveloped for a different use, or handed back to a landlord under specific lease-exit conditions, so confirming the expected final condition early in the project avoids rework at the end.
Real-World Project Experience
Projects of this type often begin the same way: a facility manager or property owner has identified switchgear, panelboards or busway that need to come out ahead of a renovation, tenant improvement, equipment upgrade or facility closure, but isn’t sure how the removal will affect operations still running in the building. From our experience, the sequence typically starts with a site walk to document existing equipment and confirm isolation points, followed by a phased removal plan built around available shutdown windows. On facilities with mixed old and new equipment, such as a legacy Westinghouse or ITE switchgear lineup being replaced by newer Square D or Eaton gear, that phasing often matters as much as the physical removal itself, since the old and new systems may need to be cross-connected temporarily during the transition.
Serving Bakersfield and the Surrounding Kern County Market
USA Decom provides electrical equipment removal services for facilities throughout Bakersfield and the surrounding Kern County industrial base, including communities such as Delano, Shafter, Wasco, Arvin, Taft, Tehachapi and McFarland, as well as facilities along the Highway 99 industrial corridor. Whether the project involves a single electrical room in an agricultural processing plant, a multi-section switchgear replacement at an oilfield service facility, or busway and panelboard removal supporting a distribution center renovation, the same core planning principles apply: confirm what’s energized, plan the isolation and removal sequence around active operations, rig and extract equipment safely, and make disposition decisions that protect recoverable value.
Tell Us About Your Project
If you’re planning to remove switchgear, panelboards, transfer switches, busway or other electrical distribution equipment from a facility in Bakersfield or elsewhere in Kern County, use the form below to tell our team about the project. Useful details include the facility type and location, the equipment involved (manufacturer, ampacity and voltage class if known), whether the building will remain partially active during removal, site access conditions, your target schedule, and photographs of the equipment if available. That information helps us put together a removal and disposition plan suited to your specific facility and timeline.