Cooling towers rarely fail all at once. More often, a facility manager in the Permian Basin ends up staring at a tower that has outlived its process, a cell that’s been bypassed for a while, or a unit tied to equipment that’s already been decommissioned. Whether the tower sits on a rooftop mechanical deck, a ground-level pad at a gas processing plant, or a structural steel frame at a compressor station, getting it down safely and off the site is a different job than getting it built.
USA Decom removes open-circuit and closed-circuit cooling towers, fluid coolers and associated condenser-water systems for facilities throughout Midland, Odessa and the surrounding Permian Basin. This page walks through the questions we’re typically asked before a facility commits to a removal contractor, along with the practical considerations that shape scope, schedule and cost.
Why Cooling Towers Get Removed in the Permian Basin
Midland and Odessa sit at the center of one of the most productive oil and gas regions in the country, and that activity influences equipment turnover across the region’s plants, compressor stations and commercial buildings. A cooling tower removal request in this market usually traces back to one of a few situations:
- A gas processing plant, compressor station or gathering facility has replaced or relocated the process equipment the tower once served, leaving the tower stranded.
- A refinery, chemical facility or midstream operation is consolidating utilities and retiring redundant cooling capacity.
- A commercial building, hospital or office campus is replacing an aging rooftop or ground-mounted tower with a new HVAC plant.
- A property is being repositioned or sold, and the tower needs to come out as part of site cleanup or lease turnover.
- Structural or corrosion issues have made continued operation unsafe, and the tower needs to be removed before it becomes a liability.
If you have a project coming up, use the form below to tell our team about the facility, equipment and schedule.
In each case, the removal itself is only part of the project. Piping tie-ins, structural supports, electrical disconnects and, in many cases, asset recovery on recoverable components all factor into the plan.

What a Cooling Tower Removal Project Actually Involves
A cooling tower looks straightforward from the outside, but the components inside the casing each require their own removal method:
- Fans, motors and gearboxes. Induced-draft and forced-draft fan assemblies, along with speed-reducer drives such as those used on Marley-style towers, need to be de-energized, disconnected and rigged out before the fan deck or casing sections come apart.
- Fill media and drift eliminators. PVC fill packs and eliminators are typically removed as bulk material and separated for recycling or disposal depending on condition and contamination.
- Basins, louvers and casing panels. Cold-water basins, hot-water distribution decks, louvers and structural panels are unbolted or cut down in sections sized for the available access and rigging.
- Structural steel and platforms. Field-erected towers and larger factory-assembled units often sit on dedicated structural steel, access platforms and ladders that must be dismantled along with the tower itself.
- Condenser-water piping and pumps. Supply and return piping, along with the associated condenser-water pumps, usually needs to be isolated, drained and disconnected as part of the same scope, particularly when the tower removal is tied to a broader mechanical-room or plant decommissioning.
- Controls and electrical. VFDs, motor starters, level controls, water-treatment skids and associated wiring are removed and disposed of or recovered depending on condition.
We plan each of these removal steps around the specific tower configuration on site rather than treating every project the same way.
Rooftop vs. Field-Erected: Why the Removal Method Changes
The single biggest factor in a cooling tower removal plan is where the tower sits and how it was built.
Rooftop and mechanical-deck towers are common on commercial buildings, hospitals and multi-tenant office properties throughout Midland and Odessa. These are usually factory-assembled, single-cell or two-cell units — configurations similar to a Marley NC or NC Everest crossflow tower, a BAC Series 3000 or Series 1500, or an EVAPCO AT-series unit. Removal from a roof typically requires:
- Verifying roof structural capacity for staging, rigging and personnel loads before work begins
- Crane picks or roof-mounted rigging to lift disassembled sections down to grade
- Protection of the roof membrane, adjacent equipment and building access points
- Coordination with building operations if other tenants or systems remain active
Field-erected and process-scale towers, more common at refineries, gas processing plants and larger industrial facilities in the region, are built in place from structural steel, fiberglass or wood/composite framing and can span multiple cells rated well beyond 1,000 tons combined. These projects typically involve:
- Sectional dismantling of multi-cell structures rather than single-piece removal
- Heavier rigging and crane capacity to handle structural steel, fan stacks and basin sections
- Coordination with plant shutdown windows, permits and isolation procedures
- Separation of ferrous steel, PVC fill, motors and electrical components for recycling and disposal
Between these two extremes, closed-circuit fluid coolers and modular units add another layer of planning, since the internal coil bundles and casings are often handled differently than an open-circuit tower’s fill and basin sections.
How Regional Conditions Affect a Removal Project
West Texas conditions shape a cooling tower project in a few practical ways. Extended high-heat periods common to the Midland-Odessa area put real thermal load on process cooling systems, which is part of why towers here are often sized generously and run hard for years before replacement becomes necessary. Blowing dust and mineral-rich local water can also accelerate scaling and corrosion inside basins, fill sections and piping, which is worth noting when a tower is being evaluated for possible resale versus scrap.
The region’s industrial base — oil and gas production, gas processing and compression, midstream infrastructure, refining-adjacent operations and regional power generation — means facility teams here typically compare bids from contractors who understand both commercial rooftop work and heavier industrial dismantling. USA Decom provides cooling tower removal services throughout Midland, Odessa and surrounding Permian Basin communities including Big Spring, Andrews, Monahans, Pecos, Lamesa and Fort Stockton, as well as facilities further out across the broader West Texas energy corridor.
Does the Tower Have Recoverable Value?
Not every retired cooling tower is scrap. Condition, completeness, age and accessibility all factor into whether components have resale or recycling value beyond basic disposal:
- Motors, gearboxes and VFDs in working condition can sometimes be recovered for resale or reuse
- Structural steel, casing panels and basin material typically carry scrap value based on material type and weight
- Copper and other non-ferrous components in piping and electrical systems are segregated for recycling
- Intact, well-maintained factory-assembled towers occasionally have secondary-market value if removed carefully rather than cut apart
We evaluate recoverable value as part of the removal proposal rather than assuming everything goes straight to a scrap bin. In some cases, the value of recovered material and equipment can offset a portion of the overall removal cost, though this depends entirely on the specific unit and its condition.
What to Have Ready Before Requesting a Quote
A faster, more accurate quote usually comes down to having a few basic facts available:
- Tower manufacturer and model, if known (a nameplate photo is often enough)
- Approximate tonnage and number of cells
- Whether the tower is rooftop, ground-mounted or field-erected
- Current operational status — running, idle, or already isolated
- Site access conditions, including crane staging area and any roof or structural limitations
- Whether associated piping, pumps or controls need to be included in scope
- Target removal timeline and any shutdown or turnover deadlines tied to the project
Photos of the tower, the surrounding access route and the nameplate go a long way toward an accurate initial assessment before a site visit is scheduled.

A Practical Pre-Removal Checklist
Before mobilization, most cooling tower removal projects benefit from confirming the following:
- Process and makeup water lines isolated and drained
- Electrical disconnects locked out and verified
- Structural condition of the roof, deck or support steel assessed
- Crane or rigging access route confirmed, including overhead obstructions
- Water treatment chemicals or residual sludge in the basin identified for proper handling
- Adjacent equipment, personnel walkways and active operations identified and protected
- Disposition plan set for recoverable equipment vs. scrap material
- Final site condition and turnover requirements agreed upon with the property owner or facility manager
Working through this list early helps avoid schedule surprises once crews and equipment are on site.
From the Field: Cooling Tower Projects We’ve Handled
Our experience with cooling tower removal spans both ends of the spectrum common to this region. On rooftop projects, our team typically plans around roof-load limits, crane staging in constrained parking or setback areas, and sequencing that keeps a building’s remaining HVAC systems undisturbed. On field-erected and process-scale removals, the sequence generally shifts toward structural steel dismantling, coordination with plant isolation procedures, and separating recoverable motors, drives and controls from bulk structural and fill material before hauling. Each project’s rigging plan, crew size and schedule are built around the specific tower configuration, access conditions and the facility’s operational requirements.
Tell Us About Your Cooling Tower Project
If you’re planning to remove a cooling tower in Midland, Odessa or elsewhere in the Permian Basin, use the form below to tell our team about the facility, the tower’s size and configuration, current access conditions, and your target schedule. Photos of the tower and its nameplate help us provide a more accurate initial assessment. Whether the project involves a single rooftop unit or a multi-cell field-erected system tied to a larger plant shutdown, we’ll work with you to scope a removal plan that fits your site and timeline.